Service Hints
TURN SIGNAL FLASHER(6)1-Ground: Changes from Approx. 12 Volts to 0 Volts with Ignition SW ON and turn signal SW Left or Right, or with Hazard SW ON
(6)2-Ground: Approx. 12 Volts with Ignition SW ON or Hazard SW ON
(6)3-Ground: Always continuity