Without Driving Position Memory
R 8 REMOTE CONTROL MIRROR SW
3-GROUND: Approx. 12 Volts with Ignition SW at ACC or ON position
7-8: Continuity with operation SW at LEFT or UP position
3-7: Continuity with operation SW at RIGHT or DOWN position
8-GROUND: Always continuity