Variable Induction Control Actuator: Testing and Inspection
INSPECTION1. With 53.3 kPa (15.75 in Hg) of vacuum applied to the Actuator, check that the Actuator rod moves. If the operation is not as specified, turn the adjusting screw.
2. One minute after applying the vacuum in step 1, check that the actuator rod does not return. If the operation is not as specified, replace the Intake Air Control Valve assembly.