Service Hints
G 2-A GENERATOR (ALL ALTERNATOR)A-1-Ground: 13.9-15.1 Volts with Engine running at 2000 RPM and 25°C (77°F)
13.5-14.3 Volts with Engine running at 5000 RPM and 115°C (239°F)
A-2-Ground: 0-4 volts with ignition SW at ON position and Engine not running