Ignition Relay: Testing and Inspection
Ignition Relay Inspection - Checking Continuity:
Inspect relay continuity
(a) Using an ohmmeter, check that there is continuity between terminals 3 and 6.
(b) Check that there is continuity between terminals 4 and 5.
(c) Check that there is no continuity between terminals 1 and 2.
If continuity is not as specified, replace the relay.
Ignition Relay Inspection - Checking Operation:
Inspect relay operation
(a) Apply battery voltage across terminals 3 and 6.
(b) Using an ohmmeter, check that there is continuity between terminals 1 and 2.
Ignition Relay Inspection - Checking Operation:
(c) Apply battery voltage across terminals 4 and 5.
(d) Using an ohmmeter, check that there is continuity between terminals 1 and 2.
If operation is not as specified, replace the relay.