Blower Motor: Service and Repair
1. Disconnect battery ground cable and disable airbag system as described under MAINTENANCE PROCEDURE/AIRBAG SYSTEM DISARMING.
2. Remove glove box.
3. Lift up front of carpet, then remove two nuts and ECU cover.
4. Remove electrical connector bracket and disconnect connector.
5. Remove three mounting screws and blower motor.