Valve Body: Testing and Inspection





U660F AUTOMATIC TRANSMISSION / TRANSAXLE: VALVE BODY ASSEMBLY: INSPECTION

1. INSPECT SHIFT SOLENOID VALVE SL

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery to the terminal of the solenoid connector, and a negative (-) lead to the solenoid body, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

2. INSPECT SHIFT SOLENOID VALVE SLT

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

3. INSPECT SHIFT SOLENOID VALVE SLU

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

4. INSPECT SHIFT SOLENOID VALVE SL1

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

5. INSPECT SHIFT SOLENOID VALVE SL2

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

6. INSPECT SHIFT SOLENOID VALVE SL3

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.

7. INSPECT SHIFT SOLENOID VALVE SL4

(a) Measure the resistance according to the value(s) in the table below.





Standard Resistance:





Text in Illustration





If the value is not as specified, replace the shift solenoid valve.

(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.

NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

OK:

The valve moves and makes an operating sound.

If the operation cannot be done as specified, replace the shift solenoid valve.