Installation
HEATING / AIR CONDITIONING: ROOM TEMPERATURE SENSOR: INSTALLATION
1. INSTALL ROOM TEMPERATURE SENSOR
(a) Connect the connector and aspirator pipe.
Text in Illustration
(b) Engage the 2 claws to install the room temperature sensor as shown in the illustration.
2. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY Installation
3. INSTALL NO. 1 SWITCH HOLE BASE Installation
4. INSTALL INSTRUMENT PANEL GARNISH LH Installation
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL (w/ Air Suspension)
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.