Diagnostic Strategies
R5 REMOTE CONTROL MIRROR SW6-10 : Continuity with the operation SW at UP or LEFT position
9-6 : Continuity with the operation SW at DOWN or RIGHT position
9-GROUND : Approx 12 volts with the ignition SW at ACC or ON position
10-GROUND : Always continuity