Temperature Control Actuator
Inspection
1. Ignition "OFF"
2. Disconnect the connector of temperature control actuator.
3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7.
Verify that the temperature control actuator operates to the cool position when connecting in the reverse.
Specification