Scantool Diagnostics
Air Conditioner
U0155 Lost Communication With Instrument Panel Cluster (IPC) Control Module - Scantool Diagnostics
Monitor Scantool data
1. Connect GDS to DLC.
2. Check for CLU DTC(s).
> Check for any related CAN DTC(s) and repair or replace as necessary. Clear DTC(s) and confirm no DTC(s) return.
> This is a intermittent problem caused by poor contact of Control Module.
> Thoroughly check the looseness, poor connection, bent, corrison, contamination, deformation or damage of connector.