Scantool Diagnostics
Motor Driven Power Steering
C1109 IGN Signal Error - Scantool Diagnostics
Monitor Scantool Data
1. Connect scantool to Data Link Connector(DLC).
2. Start engine and turn the headight and the heatwire on.
3. Monitor the "BATTERY VOLTAGE" parameter on the scantool.
4. Maintaining ENG. RPM at 2,500RPM(idle) over 2 minutes.
Specification :less than 16 [V] or more than 10 [V].
5. Is parameter within specifications?