Positive Crankcase Ventilation Valve: Service and Repair
Removal
1. Disconnect the vapor hose (A).
2. Remove the PCV valve (B).
Inspection
1. Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that there is the plunger movement.
NOTE:
If the plunger does not move (PCV valve is clogged), clean or replace the valve.
Installation
1. Installation is reverse of removal.
PCV Valve installation:
1.9 - 2.8 N.m (0.19 - 0.29 kgf.m, 1.4 - 2.1 lb-ft)