Hazard Warning Switch: Service and Repair
Inspection
Hazard Lamp Switch
1. Disconnect the negative (-) battery terminal.
2. Remove the crash pad center facia panel(A).
NOTE:
Take care not to scratch the crash pad and related parts.
3. Disconnect the hazard lamp switch connector.
4. Operate the switch and check for continuity between terminals with an ohmmeter.
Hazard Lamp Relay
1. Disconnect the negative (-) battery terminal.
2. Disconnect the ICM relay box connector.
3. Check for continuity between terminals. There should be continuity between the No.3 and No.12 or No.7 of ICM-B terminals when power and ground are connected to the No.3 and No.17 of ICM-B terminals.
4. There should be no continuity between the No.3 and No.12 or No.7 of ICM-B terminals when power is disconnected to the No.3 and No.17 of ICM-B terminals.