Component Inspection
P0448 Evaporative Emission System
Vent Control Circuit Shorted - Inspection/Repair:_:Component Inspection
Component Inspection
1. Ignition "OFF"
2. Disconnect CCV connector
3. Measure resistance between Power terminal and Control terminal of the CCV connector (Component side)
Specification : Approx. 17±1.5 at 20 °C (68 °F)
4. Is resistance within the specification?