System Inspection
P0561 System Voltage Unstable
Inspection/Repair - System Inspection
System Inspection
Alternator circuit check
1. IG KEY "OFF".
2. Disconnect alternator connector.
3. IG KEY "ON" & ENG "OFF"
4. Measure the voltage between L terminal of alternator harness connector and chassis ground.
5. Measure the voltage between FR terminal of alternator harness connector and chassis ground.
6. Is the measured voltage within specification?