W/Harness Inspection
P0459 Evaporative Emission System Purge Control Valve Circuit High
Inspection/Repair - W/Harness Inspection
Terminal & Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Control Circuit Inspection
Check Short in signal circuit
1. IG KEY "OFF".
2. Disconnect PCSV connector.
3. IG KEY "ON" & ENG "OFF"
4. Measure the voltage between control terminal of PCSV harness connector and chassis ground.
Specification : Approx 3.5 V
5. Is the measured voltage within specification?