W/Harness Inspection
P0342 Camshaft Position Sensor A Circuit Low Input (Bank 1)
Inspection/Repair - W/Harness Inspection
Terminal & Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Check Open or Short in power circuit
1. IG KEY "OFF".
2. Disconnect CMPS connector.
3. IG KEY "ON" & ENG "OFF"
4. Measure the voltage between power terminal of CMPS harness connector and chassis ground.
Specification : Approx B+
5. Is the measured voltage within specification?
Signal Circuit Inspection
Check Short in signal circuit
1. IG KEY "OFF".
2. Disconnect CMPS connector.
3. IG KEY "ON" & ENG "OFF"
4. Measure the voltage between signal terminal of CMPS harness connector and chassis ground.
Specification : Approx 12 V
5. Is the measured voltage within specification?