Hybrid Battery Service Switch: Service and Repair
Removal
WARNING:
This hybrid system uses a DC 270V voltage system. Be sure to follow safety instructions below. Failure to follow safety instructions may result in serious injury or electrocution .
1. Turn the ignition switch OFF and disconnect the auxiliary 12V battery negative (-) cable.
2. Open the safety plug service Cover (A).
3. Rotate the lever (A) in the direction of the arrow with the locking hook (B) lifted, and then pull the safety plug.
Installation
WARNING:
This hybrid system uses a DC 270V voltage system. Be sure to follow safety instructions below. Failure to follow safety instructions may result in serious injury or electrocution .
1. Installation is reverse of removal.