Refrigerant Pressure Sensor / Switch: Testing and Inspection
Inspection
1. Measure the pressure of high pressure line by voltage output between NO.1 and NO.2 terminals
2. Determine if the voltage is within spec.
Voltage =0.00878835 * Pressure + 0.37081095 [PSIA]
3. If the measured voltage value is not within specification, replace the A/C pressure transducer.