Repair Procedures
Replacement
1. Disconnect the battery negative cable.
2. Remove the air cleaner assembly (A).
3. Disconnect the starter cable (B) from the B terminal on the solenoid, then disconnect the connector (A) from the S terminal.
4. Remove the 2 bolts holding the starter, then remove the starter.
Tightening torque :
42.2 - 53.9 Nm (4.3 - 5.5 kgf.m, 31.1 - 39.8 Ib-ft)
5. Installation is the reverse of removal.
6. Connect the battery negative cable to the battery.