Scantool Diagnostics
Engine Control
P0125 Insufficient Coolant Temperature for Closed Loop Fuel Control - Scantool Diagnostics:_:Monitor DTC Staus
Monitor DTC Status
1. Check DTC Status
(1) Connect scantool to Data Link Connector(DLC).
(2) IG "ON".
(3) Select "Diagnostic Trouble Codes(DTCs)" mode, and then Press F5(INFO) to check DTC's information from the DTCs menu
(4) Read "DTC Status" parameter.
(5) Is parameter displayed "Present fault"?
YES
1) Go to "Component Inspection" procedure.
NO
1) Fault is intermittent, go to "Verification of vehicle Repair" procedure.