Component Inspection
P0453 Evaporative Emission System-Pressure Sensor High Input
Inspection/Repair - Component Inspection
Component Inspection
Check FTPS
1. IG "OFF" and connect scantool to DLC (Data Link Connector).
2. Monitor "FTPS" parameter on service data.
Specification :Approx. 15.5 - 18.5 Ohms (20°C (68°F))
3. Is the "FTPS" parameter on the service data O.K?