W/Harness Inspection
P0605 Internal Control Module Read Only Memory (ROM) Error
Inspection/Repair - W/Harness Inspection
Back Up Voltage Inspection
1. Ignition "OFF"
2. Disconnect PCM connector.
3. Ignition "ON"
4. Measure voltage between terminal 6 of the PCM harness connector and chassis ground.
Specification :Remain stable at battery voltage
5. Are circuits remaining stable at battery voltage?