Positive Crankcase Ventilation Valve: Testing and Inspection
Inspection
1. Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.
NOTE:
If the plunger does not move (PCV valve is clogged), clean or replace the valve.