CVVT Oil Control Valve (OCV)
Component Inspection
1. Turn ignition switch OFF.
2. Disconnect OCV connector.
3. Measure resistance between OCV terminals 1 and 2.
4. Check that the resistance is within the specification.
Specification: Refer to Specification section.