Trip Computer: Testing and Inspection
INSPECTION
TRIP SWITCH
1. Disconnect the negative (-) battery terminal.
2. Remove the cluster facia panel (A) after loosening 2 screws.
3. Pull out the cluster (A) from the housing after removing 4 screws.
4. Disconnect the cluster connecters and then remove the cluster.
5. Remove the cluster facia panel (A).
6. Check for continuity between the terminals in each switch position according to the table.