Component Inspection
PCSV Inspection
1. Ignition "OFF"
2. Disconnect the hose leading from the PCSV to intake manifold at intake manifold.
3. Using a vacuum pump, apply vacuum to the manifold side of the vacuum hose and verify PCSV holds vacuum.
4. Ignition "ON" & Engine "OFF"
5. Install GDS and select "Canister Purge Valve" on the Actuation Test mode
6. Activates "Canister Purge Valve" by clicking "Start" icon.
7. Verify PCSV release vacuum while valve is activating (should hear a faint click from PCSV)
8. Repeat this procedure 4 or 5 times to ensure PCSV reliability.
Specification :
9. Is PCSV working properly?