Power Door Lock Relay: Testing and Inspection
Inspection
1. Disconnect the negative (-) battery terminal.
2. Remove the junction box.
3. Check for continuity between the terminals.
Door Lock
1. There should be continuity between the No.12 and No.9 terminals in the I/P-D when power and ground are connected to the No.12 terminal in the I/P-E and No.9 terminal in the I/P-D.
2. There should be no continuity between the No.12 terminal in the I/P-E and No.9 terminal in the I/P-D when power is disconnected.
Door Unlock
1. There should be continuity between the No.3 terminal in the I/P-E and No.9 terminal in the I/P-D when power and ground are connected to the No.11 terminal in the I/P-E and No.9 terminal in the I/P-D.
2. There should be no continuity between the No.11 terminal in the I/P-E and No.9 terminal in the I/P-D when power is disconnected.