W/Harness Inspection
Terminal and Connector inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration or damage.
3. Has a problem been found?
Power Circuit Inspection
Check Voltage
1. IG "OFF" and disconnect Cooling fan relay (low).
2. IG "ON".
3. Measure voltage between battery power supply terminals of Cooling fan relay (low) harness connector and chassis ground.
Specification : Approx. B+
4. Is the measured voltage within specification?
Control Circuit Inspection
Check signal waveform
1. IG "OFF" and disconnect Cooling fan relay (low).
2. IG "ON".
3. Measure voltage between Cooling fan relay control (Low) terminal of Cooling fan relay (low) harness connector and chassis ground.
Specification : Approx. 2.7V
4. Is the measured voltage within specifications?