General Information
Component Location
General Description
The mode control actuator mounted on heater unit adjusts position of mode door by operating Direction Motor in accordance with signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of vent-> B/L -> floor -> mix.
DTC Description
The ECM sets DTC B2409 if the direction motor doesn't move to intended position within 40 sec (The ECM attempts to move the temp door for a 2 second duration at a frequency of 3 times every 20 seconds before storing a DTC.)
DTC Detecting Condition
Schematic Diagram
Signal Waveform
** Voltage value of Direction potentiometer as a function of position of mode switch