FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Variable Valve Timing Actuator: Testing and Inspection





INSPECTION

The Continuously Variable Valve Timing (CVVT) system controls the amount of valve overlap by varying the amount of oil flow into an assembly mounted on each intake camshaft through PCM control of an oil control valve. This system uses two oil control valves, one on each bank. An Oil Temperature Sensor (OTS) is used to allow PCM monitoring of engine oil temperature. As oil is directed into the chambers of the CVVT assembly, the cam phase is changed to suit various performance and emissions requirements.
1. When camshaft rotates in the direction of engine rotation: Intake-Advance / Exhaust-Retard
2. When camshaft rotates in the opposite direction of engine rotation: Intake- Retard / Exhaust- Advance




SPECIFICATION






CIRCUIT DIAGRAM





COMPONENT INSPECTION
1. Turn ignition switch OFF.
2. Disconnect OCV connector.
3. Measure resistance between OCV terminals 1 and 2.




4. Check that the resistance is within the specification.

Specification: Refer to SPECIFICATION.