Hydraulic Pressure Test
TROUBLESHOOTING
Hydraulic pressure test
1. Warm up the engine until the automatic transaxle fluid temperature is 80 - 100°C(176 - 212°F).
2. Jack up the vehicle so that the wheels are free to turn.
3. Connect the engine tachometer.
4. Connect the oil pressure gauge(09452-21500) and the oil pressure gauge adapter(09452-21002, 09452-21001) to each pressure discharge port. But use the gauge(30kg/cm2) when measuring the reverse pressure, front clutch pressure and low&reverse brake pressure.
5. If a value is outside the standard range, correct the problem while referring to the hydraulic pressure test diagnosis table.