ICM (Integrated Circuit Module) Relay Box
ICM (INTEGRATED CIRCUIT MODULE) RELAY BOXINSPECTION
SEAT WARMER
Check for continuity between the terminals.
1. There should be continuity between the No.7 and No.17 terminals when power and ground are connected to the No.14 and No.15 in the ICM-A.
2. There should be no continuity between the No.7 and No.17 terminals when power is disconnected.
BURGLAR ALARM
Check for continuity between the terminals.
1. There should be continuity between the N0.9 and No.10 terminals when power and ground are connected to the No.1 and N0.9 in the ICM-B.
2. There should be no continuity between the N0.9 and No.10 terminals when power is disconnected.
BURGLAR ALARM HORN
Check for continuity between the terminals.
1. There should be continuity between the No.12 and No.11 terminals when power and ground are connected to the No.4 and No.1 I terminals in the ICM-B.
2. There should be no continuity between the No.15 and No. 14 terminals when power is disconnected.
HAZARD LAMP
Check for continuity between the terminals.
1. There should be continuity between the No.15 and No.14 terminals when power and ground are connected to the No.5 and No.15 terminals in the ICM-B.