FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Refrigerant Pressure Sensor / Switch: Testing and Inspection

A/C PRESSURE TRANSDUCER

INSPECTION




1. Measure the pressure of high pressure line by measuring voltage output between No.1 and No. 2 terminals.
2. Inspect the voltage value whether it is sufficient to be regular value or not.

Voltage = 0.00878835 * Pressure (Psig) + 0.5

3. If the measured voltage value is not within specification, replace the A/C pressure transducer.