Low and Reverse Brake End Play Adjustment
LOW AND REVERSE BRAKE END PLAY ADJUSTMENTReverse the transmission and install the dial gauge. Move the special tool up and down to measure the end play.
Standard value: 1.35 - 1.81 mm (0.0531 - 0.0713inch)
To obtain a reference value, select a pressure plate whose thickness is within the following value. [A (moving amount) + thickness of the special tool - 1.81 (0.0531)] to [A (moving amount) + thickness of the special tool - 1.35(0.0713)].