Power Distribution Relay: Testing and Inspection
ICM (INTEGRATED CIRCUIT MODULE) RELAY BOXINSPECTION
HAZARD LAMP RELAY
Check for continuity between the terminals.
1. There should be continuity between the No. 8 and No. 6 terminals when power and ground are connected to the No. 8 and No. 9 terminals.
2. There should be no continuity between the No. 8 and No. 6 terminals when power is disconnected.
BURGLAR ALARM HORN
Check for continuity between the terminals.
1. There should be continuity between the No. 11 and No. 4 terminals when power and ground are connected to the No. 11 and No. 3 terminals.
2. There should be no continuity between the No. 11 and No. 4 terminals when power is disconnected.
BURGLAR ALARM
Check for continuity between the terminals.
1. There should be no continuity between the No. 1 and No. 5 terminals when power and ground are connected to the No. 1 and No. 2 terminals.
2. There should be continuity between the No. 1 and No. 5 terminals when power is disconnected.