Anti-Theft Function
ANTI-THEFT FUNCTION1. Arm function
Time specification
T1: 0.5 sec.
T2: 1.0 ± 0.1 sec.
T3: Max 0.6 sec.
2. Disarm function
Time specification
T1: 0.5 sec.
T2: 1 ± 0.1 sec.
T3: 30 sec.
3. Alarm function
1. Time specification
T1: 27 - 30 sec.
T2: 10 - 13 sec.
T3: 0.5 ± 0.1 sec.
2. Battery is separated during the alarm state
3. New alarm occurs during the alarm state
4. TX trunk open button pressed during the alarm state.
Time specification
T1 : 0.5 sec.
5. TX unlock button pressed during the alarm state
Time specification
T1 : 0.5 sec.
6. TX lock button pressed when the door closed during the alarm state
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.1 sec.
TX lock button pressed when the door opened during the alarm state
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.1 sec.
7. New alarm occurs when all doors closed & lock after the alarm state
Time specification
T1: 27 - 30 sec.
T2: 10 - 13 sec.
T3: 0.5 ± 0.1 sec.
8. New alarm occurs when some doors opened after alarm state
Time specification
T1: 27 - 30 sec.
T2: 10 - 13 sec.
T3: 0.5 ± 0.1 sec.
9. In case of using the door key.
T1 : 2 sec.
4. Alarm cancel
1. Time specification
T1 : 30 sec.
5. Panic
1. Time specification
T1 : 200 msec.
T2 : 27 ± 2 sec.
T3 : 0.5 ± 0.1 sec.