Assist Door Module
FAIL-SAFE FUNCTION1. If the position sensor shows no input change (driving for 5 seconds) above 60 mV while the motor is in operation, it automatically stops the operation judging that wire short, motor failure, or sensor failure.
2. Mirror drive signal cannot be outputted for more than 15 seconds in one direction. (In case of memory replay or manual switch operation)
3. Monitoring of replay execution time
If replay operation does not complete within 40 seconds from replay starting time, mirror motor stops the output and terminates the replay control.