Compressor HVAC: Service and Repair
REMOVAL1. Discharge the refrigerant.
2. Remove the drive belt after loosening the tension pulley.
3. Remove the discharge and suction hoses.
4. Disconnect the connector
5. Remove the compressor.
NOTE:
- Plug all the open fittings immediately to keep moisture out of the system.
- Do not remove plugs until ready for connection.
- Evacuate, charge and test the refrigeration system.
INSTALLATION
1. Make sure of the color of compressor mounting bolts, and then tighten it A->B->C->D order.
2. Set the tension of belt after installation.