Receiver Dryer: Service and Repair
1. Discharge refrigeration system. (Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.)2. Remove receiver drier as shown in figure.
NOTE: Immediately plug open fittings to keep moisture out of system.
3. Install receiver drier in reverse order of removal.
NOTE:
a. Apply clean compressor oil to O-rings before connecting fittings.
b. Do not apply compressor oil to fitting nuts.
c. When installing a new receiver/drier, add compressor oil through high-pressure pipe port of compressor.
Compressor oil: 0.61 cu in (10 cc)
Tightening Torque
Receiver drier inlet: 43 - 61 lb-in (4.9 - 6.9 N.m, 50 - 70 kg-cm)