Air Cleaner Housing: Service and Repair
REMOVAL
1. Remove the air intake hose and air duct connected to the air cleaner, and the resonator.
2. Remove the three bolts attaching the air cleaner mounting brackets.
3. Detach the air cleaner.
INSPECTION
1. Check the air cleaner body, cover, or packing for distortion, corrosion or damage.
2. Check the air duct for damage.
3. Check the air cleaner element for restriction, contamination or damage. If the element is slightly restricted, remove the dust and other contaminants by blowing to the inside through the element.
4. Check the air cleaner housing for restriction, contamination or damage.
5. Check the resonator for damage.
INSTALLATION
Install the air cleaner according to the reverse order of removal.