Condenser HVAC: Service and Repair
Condenser Removal:
Condenser
Removal
1. Discharge refrigeration system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
2. Remove liquid pipes.
3. Remove condenser as shown.
NOTE:
a. Insert protector such as cardboard between condenser and radiator.
b. Immediately plug open fittings to keep moisture out of system.
Installation
1. Install condenser in reverse order of removal.
NOTE:
a. Apply clean compressor oil to O-rings before connecting fittings.
b. Do not apply compressor oil to fitting nuts.
c. Remove protector before installing radiator brackets.
d. When installing a new condenser, add compressor oil through high-pressure pipe port of compressor.
Compressor oil 1.22 cu in (20 cc)
Tightening torque: Condenser inlet: 87-174 lb-in (9.8-19.6 N.m, 1.0 - 2.0 kg-m)