FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Blower Motor: Service and Repair

Blower/Evaporator
REMOVAL




1. Discharge refrigerant from A/C system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
2. Disconnect inlet and outlet pipe from evaporator.

NOTE: Immediately plug all open fittings to keep moisture out of system.

3. Remove cover and drain hose.
4. Remove instrument panel and disconnect wiring harness connector. Dashboard / Instrument Panel




5. Remove blower unit.

INSTALLATION
1. Install in reverse order of removal.
2. Evacuate refrigerant system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.
3. Charge A/C system. Refer to operating instructions of your refrigerant recovery/recycling/charging station for proper procedures.