Charging System: Service and Repair
1. Remove A/C and P/S drive belt, if equipped.2. Loosen generator mounting bolt and adjusting bolt.
3. Remove generator belt.
4. Install new generator belt and adjust to specification.
5. Tighten all bolts to specified torque.
Tightening torque
Mounting bolt:
27-38 lb-ft (37-52 N.m, 3.8-5.3 kg-m)
Adjusting bolt:
14-18 lb-ft (19-26 N.m, 1.9-2.6 kg-m)
6. Install A/C and P/S drive belt, if equipped, and adjust to specification.