Air Cleaner Housing: Service and Repair
REMOVAL1. Disconnect intake air temperature sensor connector.
2. Disconnect mass air flow sensor connector.
3. Disconnect resonance chamber hose from air cleaner housing.
4. Loosen clamp and disconnect air intake hose from mass air flow sensor.
5. Remove two bolts and remove air cleaner assembly.
INSTALLATION
1. Position air cleaner housing in place and install two bolts.
Tightening torque: 18 lb-ft (25 N.m, 2.6 kg-cm)
2. Reconnect air intake hose to mass air flow sensor and tighten clamp.
3. Reconnect resonance chamber hose.
4. Reconnect mass air flow sensor and intake air temperature sensor connectors.