A/C - Evaporator Rumbling Noise
SOURCE: Kia Technician Times
TITLE: Evaporator Noise
APPLIES TO: 98-99 Sephia
SERVICE TIP:
CONDITION
Rumbling noise coming from the evaporator area when the A/C is turned on. This noise is particularly noticeable when the vehicle is at idle.
CAUSE
This condition is caused by expansion valve refrigerant noise.
CORRECTIVE ACTION
Replace expansion valve with newly revised expansion valve (P/N 1K2A1-61-J11). Use new O-rings (P/N 1K2A1-76-461, 1 ea. and 1K2A2-76-461, 3 ea.) when installing valve.