Shift Interlock Cable: Service and Repair
1. Disconnect battery ground cable.Fig. 18 Shift Lock Actuator Replacement:
Fig. 23 Shift Selector Cable Replacement:
2. Remove components in numerical order, refer to Figs. 18 and 23.
3. Reverse procedure to install noting the following:
a. Shift selector lever to P range.
b. Push selector range against P range and hold.
c. Torque selector cable mounting bolts to 70-95 inch lbs.