FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Up to VIN S5219999

Battery voltage is supplied at all times to both the coil and the contacts of the horn relay from the STOP fuse. When the horn switch is pressed, the coil of the horn relay is grounded through the horn switch. The horn relay energizes and applies battery voltage to the horn. The horn sounds. The horn can also be grounded through the electronic time and alarm control module.