Up to VIN S5219999
Battery voltage is supplied at all times to both the coil and the contacts of the
horn relay from the STOP fuse. When the
horn switch is pressed, the coil of the horn relay is grounded through the horn switch. The horn relay energizes and applies battery voltage to the
horn. The horn sounds. The horn can also be grounded through the electronic time and alarm control module.