Evaporative Emission Control Canister: Service and Repair
Removal
1. Disconnect the canister close valve connector (A).
2. Disconnect the ventilation tube quick-connector (B) and the vapor tube quick-connectors (C, D).
3. Remove the installation bolts (A) and nut (B), and then remove the canister.
Inspection
1. Check for the following items visually.
- Cracks or leakage of the canister
- Loose connection, distortion, or damage of the vapor hose/tube
A: Canister <-> Atmosphere
B: Canister <-> Fuel Tank
C: Canister <-> Intake Manifold
Installation
Installation is the reverse of removal.
Canister installation bolt/nut:
3.9 - 5.9 N.m (0.4 - 0.6 kgf.m, 2.9 - 4.3 lb-ft)